A roof that generates, not a roof with panels added.
The BIPV solar shingle tile is a photovoltaic roofing tile that replaces conventional roof sheeting. Monocrystalline cells are laminated under low-iron tempered glass in a metal-shingle profile, wired as standard roof-integrated strings.
Because the tile is the roof, you are not paying twice — once for a covering and again for a mounting system laid over it. There are no rails and no roof penetrations.

Four routes, three of them priced today.
Colour is a specification decision, not a cosmetic one. Two of these routes generate the same power as black; one gives some away; one does not exist as a product yet.
All-black tile
TG-SS-80B · Black glass, black bottom
The stock platform, and the highest-output route.
Black glass, coloured surround
TG-SS-80CB · Coloured bottom surround
Same output as black. The colour sits below the glass, so there is no penalty.
Whole-tile red
TG-SS-65R · Red glass and red bottom
For streetscapes that have to read as terracotta. Minimum order quantity and extra cost apply.
Green — sample route
TG-SS-G · Any construction
Sample production only. No STC data or model code exists until a sample is produced.
Whole-tile red carries an 18.8 % power penalty against black (65 W against 80 W). The coloured-bottom route carries no penalty. Green has no STC data and no model code until a sample is produced, so we will not quote a figure for it.
Reproduced from the data sheet.
Every figure below is transcribed from Techengy data sheet TG-DS-20261020-01 Rev 3. These are specification values for the certified platform; project-specific figures are confirmed on samples and in the written quotation. This page is not an offer.
Electrical parameters at STC
1000 W/m², 25 °C, AM1.5.
| Parameter | TG-SS-80B | TG-SS-80CB | TG-SS-65R |
|---|---|---|---|
| Maximum power (Pmax) | 80 W | 80 W | 65 W |
| Module efficiency | 19.4 % | 19.4 % | 15.7 % |
| Voltage at Pmax (Vmpp) | 14.30 V | 14.30 V | 14.55 V |
| Current at Pmax (Impp) | 5.60 A | 5.60 A | 5.02 A |
| Open-circuit voltage (Voc) | 17.60 V | 17.60 V | 17.53 V |
| Short-circuit current (Isc) | 5.70 A | 5.70 A | 5.32 A |
Physical
- Tile dimensions
- 1340 × 420 mm
- Exposed dimensions
- 1260 × 370 mm
- Weight
- 6.5 kg per tile
- Solar cells
- Monocrystalline 166 × 83 mm, 2 × 13 layout
- Glass / encapsulant / back
- Low-iron tempered 3.2 mm / EVA / backsheet
- Junction box · cable · connector
- IP67 or better · 900 mm, 4 mm² · MC4
Thermal, operating and mechanical
- NOCT
- 45 ± 2 °C
- Temperature coefficient — Pmax
- −0.36 %/°C
- Temperature coefficient — Voc
- −0.30 %/°C
- Temperature coefficient — Isc
- +0.05 %/°C
- Operating temperature range
- −40 °C to +85 °C
- Maximum system voltage · series fuse
- 1500 V DC · 16 A
- Static load, front / back
- 5400 Pa (snow, wind) / 2400 Pa (wind)
- Hailstone impact
- 25 mm at 23 m/s
- Minimum roof slope
- 15°
What the colour actually costs you.
Taken from a reference layout on a 32° pitch. The absolute numbers belong to that roof, not to yours — the ratios are what travel.
| Route | Array | Indicative yield | Against black |
|---|---|---|---|
| Black or black glass + coloured bottom | 74.7 kWp | ~108–123 MWh/yr | No penalty |
| Whole-tile red | 60.7 kWp | ~88–100 MWh/yr | −18.8 % |
| Green (sample route) | — | — | Unquantified |
Reference yield for southern Ghana is 1,450–1,650 kWh per kWp per year. Yield scales with Pmax; colour-dependent thermal and low-light effects are second-order. Plane-by-plane azimuth assignment follows once the site north point is confirmed.
How this roof has to be built.
A 15° roof is enough
Fifteen degrees is the minimum, and anything above it is sufficient. No corrector is required above 15°, and there is no pitch-related output derating above that line.
One orientation per string
Shading falls on the whole series string, not on one tile. So every string has to sit on a single orientation and a single slope, and on hip or pyramid roofs the strings are grouped plane by plane.
Never mix colours in a string
Different colours carry different Vmpp and Impp. One colour per roof plane, always.
The string plan comes with the drawings
String layout, MPPT allocation and a plane-level shading study are issued with the engineering drawings, before anything is ordered.
Stated plainly, and evidenced on request.
The platform is certified to IEC 61215 and IEC 61730, and held to 3C, ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018. TÜV and CE certification is held for the product line. Certificate copies with the model and colour scope are available on request.
Warranty terms travel with the written proposal rather than being asserted here, because the term depends on the specification you actually buy.
This is not the right product for every roof.
New builds and re-roofs
The economics work when the roof is being replaced anyway, because the tile is the roof.
Roofs that must look right
Streetscapes and overlooked elevations, where a panel array would be the wrong answer and the roof has to read as a roof.
Pitched roofs above 15°
Below 15° this system is not appropriate. If your roof is flatter, the standard panel and rail system on the solar solutions page is the honest recommendation.
For our other solar tile range — a smaller 721 × 500 mm arched tile at 25–32 W — see solar roof tiles.
The tile is the roof, so it is laid like one.
Shingles go on course by course over battens and a waterproof underlay, exactly where the tiles would have gone. The underlay is what keeps the roof watertight while the courses are being laid — which is why this system suits a re-roof rather than being bolted onto a finished one.
Underlay first, then battens, then the course. Everything above the underlay is the roof covering, so there is no second trade waiting to be scheduled.
Roofs we have put up.
Tell us about the roof.
Tile count, string layout and yield all follow from the roof itself, so we start with the drawings, the pitch and the orientation. Send those and we will come back with a specification and a written quotation.