Techengy Solutions Group Materials Smart Home Solar Enterprise
Solar

A roof that generates, not a roof with panels added.

The BIPV solar shingle tile is a photovoltaic roofing tile that replaces conventional roof sheeting. Monocrystalline cells are laminated under low-iron tempered glass in a metal-shingle profile, wired as standard roof-integrated strings.

Because the tile is the roof, you are not paying twice — once for a covering and again for a mounting system laid over it. There are no rails and no roof penetrations.

A roof covered in dark solar tiles
The range

Four routes, three of them priced today.

Colour is a specification decision, not a cosmetic one. Two of these routes generate the same power as black; one gives some away; one does not exist as a product yet.

80 W

All-black tile

TG-SS-80B · Black glass, black bottom

The stock platform, and the highest-output route.

80 W

Black glass, coloured surround

TG-SS-80CB · Coloured bottom surround

Same output as black. The colour sits below the glass, so there is no penalty.

65 W

Whole-tile red

TG-SS-65R · Red glass and red bottom

For streetscapes that have to read as terracotta. Minimum order quantity and extra cost apply.

—

Green — sample route

TG-SS-G · Any construction

Sample production only. No STC data or model code exists until a sample is produced.

Whole-tile red carries an 18.8 % power penalty against black (65 W against 80 W). The coloured-bottom route carries no penalty. Green has no STC data and no model code until a sample is produced, so we will not quote a figure for it.

Specification

Reproduced from the data sheet.

Every figure below is transcribed from Techengy data sheet TG-DS-20261020-01 Rev 3. These are specification values for the certified platform; project-specific figures are confirmed on samples and in the written quotation. This page is not an offer.

Electrical parameters at STC

1000 W/m², 25 °C, AM1.5.

ParameterTG-SS-80BTG-SS-80CBTG-SS-65R
Maximum power (Pmax)80 W80 W65 W
Module efficiency19.4 %19.4 %15.7 %
Voltage at Pmax (Vmpp)14.30 V14.30 V14.55 V
Current at Pmax (Impp)5.60 A5.60 A5.02 A
Open-circuit voltage (Voc)17.60 V17.60 V17.53 V
Short-circuit current (Isc)5.70 A5.70 A5.32 A

Physical

Tile dimensions
1340 × 420 mm
Exposed dimensions
1260 × 370 mm
Weight
6.5 kg per tile
Solar cells
Monocrystalline 166 × 83 mm, 2 × 13 layout
Glass / encapsulant / back
Low-iron tempered 3.2 mm / EVA / backsheet
Junction box · cable · connector
IP67 or better · 900 mm, 4 mm² · MC4

Thermal, operating and mechanical

NOCT
45 ± 2 °C
Temperature coefficient — Pmax
−0.36 %/°C
Temperature coefficient — Voc
−0.30 %/°C
Temperature coefficient — Isc
+0.05 %/°C
Operating temperature range
−40 °C to +85 °C
Maximum system voltage · series fuse
1500 V DC · 16 A
Static load, front / back
5400 Pa (snow, wind) / 2400 Pa (wind)
Hailstone impact
25 mm at 23 m/s
Minimum roof slope
15°
Colour and yield

What the colour actually costs you.

Taken from a reference layout on a 32° pitch. The absolute numbers belong to that roof, not to yours — the ratios are what travel.

RouteArrayIndicative yieldAgainst black
Black or black glass + coloured bottom74.7 kWp~108–123 MWh/yrNo penalty
Whole-tile red60.7 kWp~88–100 MWh/yr−18.8 %
Green (sample route)——Unquantified

Reference yield for southern Ghana is 1,450–1,650 kWh per kWp per year. Yield scales with Pmax; colour-dependent thermal and low-light effects are second-order. Plane-by-plane azimuth assignment follows once the site north point is confirmed.

Design rules

How this roof has to be built.

A 15° roof is enough

Fifteen degrees is the minimum, and anything above it is sufficient. No corrector is required above 15°, and there is no pitch-related output derating above that line.

One orientation per string

Shading falls on the whole series string, not on one tile. So every string has to sit on a single orientation and a single slope, and on hip or pyramid roofs the strings are grouped plane by plane.

Never mix colours in a string

Different colours carry different Vmpp and Impp. One colour per roof plane, always.

The string plan comes with the drawings

String layout, MPPT allocation and a plane-level shading study are issued with the engineering drawings, before anything is ordered.

Certification

Stated plainly, and evidenced on request.

The platform is certified to IEC 61215 and IEC 61730, and held to 3C, ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018. TÜV and CE certification is held for the product line. Certificate copies with the model and colour scope are available on request.

Warranty terms travel with the written proposal rather than being asserted here, because the term depends on the specification you actually buy.

Where it fits

This is not the right product for every roof.

New builds and re-roofs

The economics work when the roof is being replaced anyway, because the tile is the roof.

Roofs that must look right

Streetscapes and overlooked elevations, where a panel array would be the wrong answer and the roof has to read as a roof.

Pitched roofs above 15°

Below 15° this system is not appropriate. If your roof is flatter, the standard panel and rail system on the solar solutions page is the honest recommendation.

For our other solar tile range — a smaller 721 × 500 mm arched tile at 25–32 W — see solar roof tiles.

How it is laid

The tile is the roof, so it is laid like one.

A row of flat solar shingles being laid over a batten grid, with a drill resting on the roof

Shingles go on course by course over battens and a waterproof underlay, exactly where the tiles would have gone. The underlay is what keeps the roof watertight while the courses are being laid — which is why this system suits a re-roof rather than being bolted onto a finished one.

Underlay first, then battens, then the course. Everything above the underlay is the roof covering, so there is no second trade waiting to be scheduled.

In application

Roofs we have put up.

A flat solar shingle roof part-way through installation, laid over waterproof membrane and timber battens
Flat shingle course going down over battens and underlay
Close-up of wavy glass solar roof tiles in dark green, seen across the roof slope
Wavy glass tile across the slope, seen along the course
A pergola roofed in wavy solar tiles with a wall of white inverters mounted beneath it
A pergola roofed in wavy tile, inverters on the wall below
A large frameless photovoltaic module being set onto roof mounting rails
A frameless module being set onto mounting rails
Next step

Tell us about the roof.

Tile count, string layout and yield all follow from the roof itself, so we start with the drawings, the pitch and the orientation. Send those and we will come back with a specification and a written quotation.